116 PREGNANCY RATES AFTER ADMINISTRATION OF EQUINE CHORIONIC GONADOTROPIN (eCG) AT PROGESTERONE INTRAVAGINAL DEVICE REMOVAL AND 14 DAYS AFTER FIXED-TIME AI IN BEEF CATTLE

R. Núñez A , T. de Castro A , L. Cutaia B , G. Bó B and A. Menchaca A
+ Author Affiliations
- Author Affiliations

A Instituto Reproducción Animal Uruguay, Fundación IRAUy, Montevideo, Uruguay;

B Instituto Reproducción Animal Córdoba, Córdoba, Argentina

Reproduction, Fertility and Development 23(1) 163-163 https://doi.org/10.1071/RDv23n1Ab116
Published: 7 December 2010

Abstract

An important proportion of embryonic deaths in cattle occur during the critical period of embryo development and maternal recognition of pregnancy. High serum progesterone concentrations during this period are associated to higher embryo survival, and the use of eCG could enhance luteal activity. Two experiments were carried out to evaluate the effect of administering eCG at the time of removal of a progesterone-releasing device and 14 days after fixed-time artificial insemination (FTAI) in beef cattle. Multiparous suckled cows between 60 and 90 days postpartum (n = 297; Exp. 1), and two-year old prepuberal heifers (n = 689; Exp. 2) with a body condition score (BCS) between 3.5 and 5 (1 to 8 scale) were used. At the beginning of the experiments, none of females used had a corpus luteum detected by ultrasonography. Females received an intravaginal device containing 0.5 g progesterone (DIB 0.5, Syntex, Buenos Aires, Argentina) and 2 mg oestradiol benzoate i.m. (Benzoato de Oestradiol, Syntex). Eight days later, 500 μg of cloprostenol (Ciclase DL, Syntex) and 0.5 mg oestradiol cypionate (Cipiosyn, Syntex) were given i.m. and devices were removed; FTAI was performed 52 to 56 h after DIB removal. At the time of device removal, the animals were randomly allocated to 4 groups, to receive 400 IU of eCG i.m. (Novormon, Syntex) or placebo at device removal and/or 14 days after FTAI, in a 2 × 2 factorial design. Control group did not receive eCG. In Exp. 1, nose plates were placed on calves on the day of DIB insertion and left for 10 days in order to prevent suckling. Pregnancy diagnosis was performed by ultrasonography at 30 and 60 days after FTAI. Data were analysed by logistic regression. Pregnancy rate at 30 days after FTAI was affected by treatment (P < 0.05; Table 1). Late embryonic/fetal loss rates (non-pregnant females at 60 days after FTAI over those pregnant at 30 days) were 1.6% (3/182) for cows in Exp. 1 and 4.8% (14/292) for heifers in Exp. 2; no differences were detected among groups. In conclusion, administration of 400 IU of eCG at device removal increases pregnancy rate, both in anestrus cows and heifers. However, the administration of a second dose of eCG 14 days after FTAI suggests a possible effect on embryo survival within the first 30 days of pregnancy in cows but not in heifers. Further studies are required to confirm these results.


Table 1.  Pregnancy rates after administration of eCG at time of progesterone device removal and/or 14 days after insemination in beef cattle
T1

Supported by Syntex.